APPLICATION: TANK, FUEL, AND BULK STORAGE
Inventory on the dashboard, level and leak alarms on the phone
Above-ground and underground tank monitoring for fuel, water, and chemical feed. RACO trends inventory where you can see it and pushes the alarm to whoever needs to act when a level or a leak crosses the line.
Data and alarms
dashboards for inventory, phones for alarms
Redundant alerts
level and leak alarms still get out in a dead zone
Analog inputs
24-bit, 4-20 mA, with wire-fault detection
What you monitor
From continuous inventory to the alarm that cannot wait
Land level, leak, and pressure signals on one Gen2 and split routine data from urgent alarms.
Level and inventory
4-20 mA level with Hi/HiHi and Lo/LoLo thresholds, trended for inventory and alarmed for extremes.
Leak detection
Overfill and pressure
Overfill floats and 4-20 mA pressure with trip delays to ignore normal swings.
Inventory trends
Product temperature
Site power and intrusion
Easy to implement
Up and running without a network project.
No carrier to choose, no IP addresses to configure, no inbound ports to open. The device ships pre-provisioned for cellular.
1. Mount and wire
Install the Gen2 in your panel and land your field signals on the spring-clamp terminals: floats, transducers, flow meters, pump status.
2. Cloud configuration
Register the device in the RACO Monitoring Center, then set channels, alarm thresholds, and your notification and escalation groups from any browser.
3. Get alerted
Receive voice, text, or email alerts with escalation. Cellular delivers first; satellite steps in if a cellular alarm isn't confirmed within 2 minutes.
Where it goes
Above ground, underground, and off the beaten path
Fuel yards, water storage, and chemical feed at sites with no operator standing by.
Fuel tanks
Level and inventory, overfill, and leak detection for above-ground and underground fuel storage.
Water storage
High and low level with overflow alarming for potable and process water tanks.
Chemical feed
Day-tank and bulk chemical level with low-level alarms to prevent a feed interruption.
Remote tank yards
Level plus power and intrusion where no one is on site.
Integrated solution
Managed in the RACO Monitoring Center.
Every Verbatim Gen2 is integrated with the RACO Monitoring Center out of the box. Configure devices, define alarms, route notifications, and review your event history from any browser, no software to install.
-
Register devices and assign them to sites
-
Configure channels, thresholds, and notification groups
-
Acknowledge alarms and review timestamped event logs
-
Remote arm and disarm for maintenance windows
-
1 year of data history included, with 3 and 5 year add-ons
Questions? We've got answers
FAQ
Can I see inventory and still get urgent alarms?
Yes, that is the design. Level and inventory trend continuously in the RACO Monitoring Center for planning, while notification routing sends the urgent conditions, low, overfill, or leak, to voice, text, and email with escalation.
Does it require network or IT configuration?
Not for standard deployments. There is no LAN access, no user IP configuration, and no inbound ports. Optional PLC and industrial-protocol integration (EtherNet/IP, Modbus TCP) is planned for a future release.
Is the Verbatim Gen2 a traditional SCADA system?
No. Its better!
It is a dedicated monitoring and alarm-notification device that supplements your existing operational systems. If you want remote monitoring, basic process control, or intuitive visualization, but you don't want all the cost, time, and complexity of a SCADA system, you'll love it. If you want sub-second PID loops and demanding ladder logic, you should consider a more traditional SCADA system.
Does it guarantee alarm delivery?
No. Notifications are best-effort and depend on factors outside RACO's control, including carrier networks and site conditions. The cellular-plus-satellite design adds a second delivery path, but you should keep local safeguards and response procedures in place.
What happens if connectivity is lost?
The device keeps monitoring inputs and running alarm logic locally, and it queues events to send when connectivity returns. It also includes a connectivity-loss alert so you know if a device stops checking in.
Which cellular carrier does it use?
A multi-carrier embedded SIM selects the best available network automatically (carriers such as AT&T, Verizon, Rogers, and Bell, by location and signal). No carrier setup is required at install.
Is the satellite the same as Starlink?
No. The Gen2 uses low-bandwidth satellite messaging on the Skylo network to transmit alarm and telemetry data. It is not broadband internet and does not require a dish or router.
Delivering legendary service
Backed by real people who know this market
RACO has manufactured industrial monitoring equipment in the United States for decades. When you call, you reach a technician, not a queue.
Live Help for Life
Free live chat with trained RACO technicians during business hours, plus a toll-free line at (800) 722-6999. Onboarding and regular refresher training at no cost.
Always-on resources
A 24/7 web support center with documentation, wiring diagrams, commissioning checklists, and FAQs, optimized for desktop and mobile.
Built to last
A 24-month hardware warranty, signed over-the-air firmware updates, and a watchdog that recovers from faults without a site visit.
Don't be shy
Talk to a RACO expert
Tell us about your sites and a real person will help you scope the right setup. No SCADA project required.