APPLICATION: PUMPS AND MOTORS

The cheapest first step: read the fault contacts you already have

Most pumps and motors already have status and fault contacts. They just have no way to be seen from off-site. RACO bolts on and turns those contacts into status, run-time, and alarms you can read from anywhere.

Verbatim Gen2 - Transparent1
Bolt-on

Uses existing contacts

no new sensors needed to start

Cell+Sat

Redundant alerts

a pump trip reaches a person, not a dead line

8

Relay outputs

for lead, lag, and simple control

What you monitor

Status and run-time today, deeper signals when you want them

Start with the dry contacts you already have, then add analog current or pressure when you are ready.

Run and fail status

Digital run and fail contacts turned into off-site status and alarms.

Run-time and cycles

Run-time totalizing and short-cycle detection to flag a pump working too hard.

Current draw

4-20 mA current as an early sign of a bearing, seal, or load problem.

Discharge pressure and flow

4-20 mA pressure and flow to see performance, not just on and off.

Power loss

Utility power-loss detection so a dead panel does not sit unnoticed.
 

Lead and lag control

Relay outputs to start and stop lead or lag pumps and alternate duty.

Easy to implement

Up and running without a network project.

No carrier to choose, no IP addresses to configure, no inbound ports to open. The device ships pre-provisioned for cellular.

1. Mount and wire

Install the Gen2 in your panel and land your field signals on the spring-clamp terminals: floats, transducers, flow meters, pump status.

2. Cloud configuration

Register the device in the RACO Monitoring Center, then set channels, alarm thresholds, and your notification and escalation groups from any browser.

3. Get alerted

Receive voice, text, or email alerts with escalation. Cellular delivers first; satellite steps in if a cellular alarm isn't confirmed within 2 minutes.

Applications

Any pump or motor worth knowing about from off-site

From a single critical pump to a fleet of them across dispersed sites.

PXL_20241024_153004601
Water and wastewater pumps

Water and wastewater pumps

Run, fail, run-time, and lead or lag control on booster and lift-station pumps.

 

digital status · pulse run-time · relay control
Irrigation and ag pumps

Irrigation and ag pumps

Pressure, run-time, and power loss on remote, off-grid pumps.

 

4-20 mA pressure · run-time · power loss
Industrial motors and blowers

Industrial motors and blowers

Run status, run-time, and current draw across the plant.

 

digital run status · 4-20 mA current
Rental and temporary pumps

Rental and temporary pumps

Fast bolt-on status and run-time on pumps that move between jobs.

 

digital status · pulse run-time

Integrated solution

Managed in the RACO Monitoring Center.

Every Verbatim Gen2 is integrated with the RACO Monitoring Center out of the box. Configure devices, define alarms, route notifications, and review your event history from any browser, no software to install.

  • Register devices and assign them to sites

  • Configure channels, thresholds, and notification groups

  • Acknowledge alarms and review timestamped event logs

  • Remote arm and disarm for maintenance windows

  • 1 year of data history included, with 3 and 5 year add-ons

Data Card - RMC - Large RTU Status - RMC - XLarge

Questions? We've got answers

FAQ

What is the minimum I need to start?

Just the fault and run contacts your pump already has. Land those on the Gen2 digital inputs and you have off-site status, run-time, and alarms. You can add analog current, pressure, or flow later on the same device.

Does it require network or IT configuration?

Not for standard deployments. There is no LAN access, no user IP configuration, and no inbound ports. Optional PLC and industrial-protocol integration (EtherNet/IP, Modbus TCP) is planned for a future release.

Is the Verbatim Gen2 a traditional SCADA system?

No. Its better! 

It is a dedicated monitoring and alarm-notification device that supplements your existing operational systems. If you want remote monitoring, basic process control, or intuitive visualization, but you don't want all the cost, time, and complexity of a SCADA system, you'll love it. If you want sub-second PID loops and demanding ladder logic, you should consider a more traditional SCADA system.

Does it guarantee alarm delivery?

No. Notifications are best-effort and depend on factors outside RACO's control, including carrier networks and site conditions. The cellular-plus-satellite design adds a second delivery path, but you should keep local safeguards and response procedures in place.

What happens if connectivity is lost?

The device keeps monitoring inputs and running alarm logic locally, and it queues events to send when connectivity returns. It also includes a connectivity-loss alert so you know if a device stops checking in.

Which cellular carrier does it use?

A multi-carrier embedded SIM selects the best available network automatically (carriers such as AT&T, Verizon, Rogers, and Bell, by location and signal). No carrier setup is required at install.

Is the satellite the same as Starlink?

No. The Gen2 uses low-bandwidth satellite messaging on the Skylo network to transmit alarm and telemetry data. It is not broadband internet and does not require a dish or router.

Delivering legendary service

Backed by real people who know this market

RACO has manufactured industrial monitoring equipment in the United States for decades. When you call, you reach a technician, not a queue.

IMG_7001

Live Help for Life

Free live chat with trained RACO technicians during business hours, plus a toll-free line at (800) 722-6999. Onboarding and regular refresher training at no cost.

Always-on resources

A 24/7 web support center with documentation, wiring diagrams, commissioning checklists, and FAQs, optimized for desktop and mobile.

Built to last

A 24-month hardware warranty, signed over-the-air firmware updates, and a watchdog that recovers from faults without a site visit.

Don't be shy

Talk to a RACO expert

Tell us about your sites and a real person will help you scope the right setup. No SCADA project required.